Q6 (16 Marks) Auxiliary Systems 🔥 Repeated 8x in exams
MEP • Written Exam

Briefly describe your action plan on following exigencies:

(a) Leaky economizer tube, while at sea

(b) Leaky intercooler of main air compressor, while maneuvering

Appeared In: Apr 2022Feb 2021Dec 2019Jun 2019Jan 2019Dec 2018Jul 2018Mar 2018

✓ Verified Model Answer (Text Solution)

Structured for DG Shipping MEO Class II examination scoring criteria.

Exam Ready
Part (a)

Leaky economizer tube at sea:

  • Immediately inform the wheelhouse to stop the engine.
  • Take control of the Engine Control Room (ECR).
  • Maintain boiler water circulation pump operation. If the hot well level is low, top it up.
  • Open the turbocharger drain to check for water ingress and leave it open.
  • After 30-60 minutes (depending on leak severity), stop the boiler water circulating pump.
  • Locate the leaking tube by opening the EGB side door, restarting the circulating pump briefly to identify the leak, then stopping the pump and closing relevant valves.
  • Use manufacturer-supplied steel plugs to seal both ends of the leaking tube using offset plugs. Steam pressure will hold them in place.
  • Restart the circulating pump, vent the economizer, and verify no further leaks.
  • Close the door.
  • Run the circulating pump for 1-2 hours before restarting the main engine.
Part (b)

Action Plan for a Leaky Intercooler in Main Air Compressor During Maneuvering

  • Immediately notify the wheelhouse about the issue to minimize engine movements, if operationally feasible, and avoid frequent start/stop cycles of the engine.
  • Shut down all non-essential services that use compressed air to reduce the demand on the main air compressor (MAC).
  • If a standby MAC is available:
    • Isolate the affected compressor.
    • Start and use the standby MAC to meet air requirements.
    • Begin troubleshooting and repairs on the faulty intercooler.
  • If no standby MAC is available:
    • Operate the compressor manually as needed to ensure sufficient compressed air supply.
    • Shut the water valve before stopping to prevent water ingress into the air side.
    • Start the compressor first and then open the water valve to ensure no water enters the air passages.
  • At the earliest safe opportunity, open the air compressor to locate and repair the leak to restore full functionality and prevent further issues.