Q1 (16 Marks) Lubrication & Bearings 🔥 Repeated 5x in exams
MEP • Written Exam

Describe how the following conditions are prevented in auxiliary boilers:

(a) Feed contamination by oil from heating coil drains

(b) Internal corrosion

(c) Furnace blowback

(d) Uptake fire

Appeared In: Dec 2025Mar 2021Jan 2021Oct 2018Feb 2018

✓ Verified Model Answer (Text Solution)

Structured for DG Shipping MEO Class II examination scoring criteria.

Exam Ready

(a) Feed Contamination by Oil from Heating Coil Drains

Prevention Measures:

  • Ensure heating coil drains are led to an observation tank or inspection glass before discharging overboard, so oil presence can be detected.
  • Provide and maintain steam traps and drain valves in good condition to avoid oil leakage into feed systems.
  • Fit non-return valves and isolating valves between heating coils and feedwater system.
  • Regularly inspect and test coil integrity to detect leaks early.
  • Avoid direct connection between heating coil drains and feedwater system without monitoring arrangements.

(b) Internal Corrosion

Prevention Measures:

  • Maintain correct boiler water treatment program to control pH and dissolved oxygen levels.
  • Use oxygen scavengers and chemical dosing as per manufacturer’s recommendations.
  • Maintain feedwater temperature in the cascade tank at about 85°C to aid oxygen release.
  • Keep feed tank and cascade tank lids/manholes closed to prevent air ingress.
  • Carry out regular blowdown to remove sludge and maintain proper alkalinity.
  • Inspect internal surfaces periodically and renew protective coatings if applied.

(c) Furnace Blowback

Prevention Measures:

  • Always carry out proper pre- and post-purging to clear combustible vapors from the furnace.
  • Maintain correct air–fuel ratio by ensuring proper functioning of air dampers, fuel regulators, and controllers.
  • Inspect and clean atomizers/burners to ensure fine fuel spray and complete combustion.
  • Check fuel viscosity and temperature to maintain correct atomization.
  • Avoid ignition attempts in a furnace containing unburnt fuel; purge thoroughly before re-lighting.
  • Ensure proper sequence and interlock functioning in the burner management system.

(d) Uptake Fire

Causes:

  • Accumulation of oily soot on tube surfaces due to incomplete combustion.
  • Poor circulation through tubes causing overheating.
  • High tube metal temperatures (>700°C).

Prevention Measures:

  • Carry out regular soot blowing and periodic washing of exhaust gas boilers to remove soot deposits.
  • Maintain proper air–fuel ratio and ensure complete combustion by checking damper and fuel control systems.
  • Ensure adequate steam and water flow in generating and superheater tubes to maintain good heat transfer and circulation.
  • Keep auxiliary blower running (manual mode if needed) to maintain airflow and prevent high exhaust temperatures during cut-off periods.
  • Maintain fuel oil injection viscosity between 12–13 cSt for correct atomization.
  • Incorporate extra soot-blowing routines when using fuels prone to high carbon deposition.