Q2 (16 Marks) Engine Construction & Components 🔥 Repeated 14x in exams
MEKM • Written Exam

With respect to Air Starting systems for 2 stroke diesel engines:

(a) Sketch and describe Main Engine starting air distributor.

(b) List the safety devices and interlocks incorporated in main engine air starting system and state the purpose of each.

Appeared In: Aug 2025Jun 2024Aug 2023Jun 2023Jan 2022Mar 2021Jan 2020Dec 2019Sep 2019Jun 2019Mar 2019Dec 2018Nov 2018Jul 2018

✓ Verified Model Answer (Text Solution)

Structured for DG Shipping MEO Class II examination scoring criteria.

Exam Ready
Part (a)

Main engine air starting distributor:

  • The starting air valve is pneumatically operated by the air distributor shown above in the sketch.
  • When the engine starting lever is operated, air is admitted to the distributor, forcing all pilot valves against the spring, onto the cam.
  • The pilot valve of the cylinder unit, which is in the correct position for admitting air, will be pushed into the depression of the cam.
  • In this position, ports 1 and 4 will be connected, and control air will act on top of the starting air valve to open it, admitting starting air to the cylinder. At the same time, ports 3 and 5 will be connected, and air below the starting air valve piston will be vented.
  • At the end of the starting air admission period in the cylinder, the pilot valve will come out of the cam depression, due to which ports 4 & 2 got connected & the opening air to the starting air valve is vented. Also, port 1 & 5 is connected, so closing air will keep the starting air valve in the closed position.
Part (b)

Safety Devices and Interlocks in the Starting Air System

  • Flame Trap/Flame Arrestor: Prevents flames from entering the airlines and reaching the air bottles in case leaking air start valve
  • Bursting Disc: Releases excessive pressure in the starting airline
  • Relief Valve: Fitted on the starting air manifold to release excessive pressure.
  • Non-Return Valve: Prevents hot gases, flames, or sparks from travelling back towards the air bottles in case of a faulty air start valve, minimising the risk of explosion.
  • Turning Gear Interlock: Prevents the engine from starting if the turning gear is engaged.
  • Running Direction Interlock: Ensures the engine will not receive fuel if its running direction does not match the specified direction on the telegraph.
  • Starting Air Distributor End Position Interlock: Prevents the engine from starting if the distributor has not reached its correct end position.
  • Lube Oil Pressure Interlock: Prevents the engine from starting if the lube oil pressure is low
  • Auxiliary Blower Interlock: Ensures the engine will not start if the auxiliary blower is not in automatic mode.