GASCO Exit Exam • Set 7 Question 21 of 30

For the LNG NO 96 containment system, why is the cargo tanks secondary insulation spaces pressure maintained slightly higher than primary insulation spaces?

✓

Direct Answer

Option A: To avoid vapor transfer into secondary insulation spaces if primary insulation spaces vapor leaks

In Gaztransport & Technigaz NO 96 membrane containment systems, Invar membranes and perlite insulation boxes maintain cargo containment and thermal insulation.

All Options

A
To avoid vapor transfer into secondary insulation spaces if primary insulation spaces vapor leaks (Correct Answer)
B
To avoid cold spot formation in inner hull
C
To reduce heat transfer and increase efficiency of insulation spaces
D
To prevent ingress of air through the leak spot into cargo tank

Detailed Explanation & Context

In Gaztransport & Technigaz NO 96 membrane containment systems, Invar membranes and perlite insulation boxes maintain cargo containment and thermal insulation.

Relevant Framework: STCW 2010 Manila Amendments • DG Shipping E-Learning & Exit Exam Standards • Advanced Training for Liquefied Gas Tanker Cargo Operations (GASCO).