You are testing a tank that contained gasoline by using a combustible gas indicator. Under testing, the tank sample caused the needle to move rapidly to 100 on the dial then fall to zero. What is the concentration of flammable gas?

✓

Direct Answer

Option C: Over the flammable range

ISGOTT guidelines state that a combustible gas indicator reading 100% LEL then falling to zero signifies an atmosphere over the flammable range. This occurs because the gas concentration is so high (above UEL) that there isn't enough oxygen for the sensor's filament to burn, indicating a gas-rich, oxygen-deficient environment.

All Options

A
Less than the flammable range
B
Within the flammable range
C
Over the flammable range (Correct Answer)
D
The explosimeter is defective and giving a false reading.

Detailed Explanation & Context

ISGOTT guidelines state that a combustible gas indicator reading 100% LEL then falling to zero signifies an atmosphere over the flammable range. This occurs because the gas concentration is so high (above UEL) that there isn't enough oxygen for the sensor's filament to burn, indicating a gas-rich, oxygen-deficient environment.

Relevant Framework: STCW 2010 Manila Amendments • DG Shipping E-Learning & Exit Exam Standards • Advanced Training for Chemical Tanker Cargo Operations (CHEMCO).

Advertisement

Practice Full CHEMCO Set 13

Test yourself with 30 interactive questions, live timer, and instant score.

Launch Practice Simulator →

Question Discussion & Notes

0

Have a doubt, memory trick, or exam update? Share your insights with fellow mariners.

Leave a Comment / Clarification

By posting, you agree to our Terms & Moderation Policy.

Loading mariner discussions...