CHEMCO Exit Exam • Set 5 Question 9 of 30

Before a tank is to be crude oil washed, the oxygen content in the tank must be measured at a position ________.

✓

Direct Answer

Option D: one meter from the deck

Oxygen content for Crude Oil Washing (COW) is measured one meter from the deck to ensure the atmosphere is below the 8% LEL, as per ISGOTT, preventing ignition during the washing process. This specific location accounts for potential stratification of gases.

All Options

A
immediately above the level of the oil
B
at the top of the tank
C
in the vent riser
D
one meter from the deck (Correct Answer)

Detailed Explanation & Context

Oxygen content for Crude Oil Washing (COW) is measured one meter from the deck to ensure the atmosphere is below the 8% LEL, as per ISGOTT, preventing ignition during the washing process. This specific location accounts for potential stratification of gases.

Relevant Framework: STCW 2010 Manila Amendments • DG Shipping E-Learning & Exit Exam Standards • Advanced Training for Chemical Tanker Cargo Operations (CHEMCO).